孔板流量計取壓口安裝方式以及注意事項 |
信息來(lái)源: 流量變送器生產(chǎn) | 2019-05-07 點(diǎn)擊量: 8559 |

孔板流量計取壓口安裝方式以及注意事項,西安華恒儀表制造:孔板流量計按國標規定進(jìn)行設計、制造和檢定的標準孔板無(wú)需實(shí)流標定,精度高、結構簡(jiǎn)單、制造成本低,但壓力損失在所有標準節流裝置中最大,不適用于要求壓力損失小的情況,標準孔板廣泛用于石油、化工、冶金、電力等行業(yè)。
Installation method and precautions of orifice plate flowmeter pressure intake port,Xi'an Huaheng Instrument Manufacture:orifice plate flowmeter designed,manufactured and calibrated according to the national standard does not need real flow calibration,has high accuracy,simple structure and low manufacturing cost,but the pressure loss is the largest in all standard throttling devices,and is not suitable for situations requiring low pressure loss.Standard orifice plate is widely used.Petroleum,chemical,metallurgical,electric power and other industries.
孔板流量計取壓口安裝方式:
Installation method of orifice flowmeter pressure tap:
1、被測流體為液體時(shí),為防止氣泡進(jìn)入導壓管,取壓口應處工藝管道中心線(xiàn)下偏≤45°的位置上,正負取壓口處于與管道對稱(chēng)位置時(shí),兩者應在同一水平面上
1.When the measured fluid is liquid,in order to prevent air bubbles from entering the pressure guide pipe,the pressure take-off port should be located at the position below 45 degrees below the center line of the process pipeline,and the positive and negative pressure take-off port should be in the symmetrical position with the pipeline,both of them should be on the same horizontal plane.
2、被測流體為氣體時(shí),為防止液體(冷凝液)進(jìn)入導壓管,取壓口應處工藝管道中心管道上方線(xiàn)上偏≤45°的位置上,正負取壓口處于與管道對稱(chēng)位置時(shí),兩者應在同一水平線(xiàn)上。
2.When the measured fluid is gas,in order to prevent the liquid(condensate)from entering the pressure guide pipe,the pressure take-off port should be located at the position of less than 45 degrees above the central pipeline of the process pipeline,and the positive and negative pressure take-off ports should be in the same horizontal line when they are in the symmetrical position with the pipeline.
3、被測流體為蒸汽時(shí),應保證冷凝器中冷凝液面恒定和正負導壓管上的冷凝面高度一致。正負壓口處于與管道對稱(chēng)位置時(shí),兩者應在同一水平面上。
3.When the measured fluid is steam,the condensate level in the condenser should be kept constant and the height of the condensation surface on the positive and negative pressure guide tubes should be consistent.When the positive and negative pressure ports are in the symmetrical position with the pipeline,they should be on the same horizontal plane.
以上三種孔板流量計取壓口安裝方式,均可與管道對稱(chēng)和管道的同一側進(jìn)行安裝。
The above three kinds of orifice flow meters can be installed symmetrically with the pipeline and on the same side of the pipeline.